Fluke Thermography Selection Guide




Ti100, Ti110, Ti125 Thermal Imagers
  Industrial-Commercial General Use
Images Ti100_image_2_tn
Model Ti125 Ti110 Ti100
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 µm to 14 µm (long wave)
Capture or refresh rate 9 Hz or 30 Hz versions 9 Hz
NETD (Thermal sensitivity) ≤ 0.10 °C at 30 °C target temp (100 mK)
FOV (Field of view) 22.5 °H x 31 °V
IFOV (Spatial resolution) 3.39 mRad
Temperature measurement range (not calibrated below -10 °C) -20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex focus system Focus-free 1.2 m (4 ft) and beyond
IR-Fusion® technology PIP, FULL IR, FULL VISIBLE, AutoBlend PIP, FULL IR, FULL VISIBLE No, full IR only
Color alarms High temperature, low temperature, isotherm High temperature
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber Blue-Red, Ironbow, Grayscale, Amber
Ultra Contrast palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber Blue-Red, Grayscale, Ironbow
Hot/cold markers Yes
User definable spot markers Three on camera and in SmartView in SmartView only
Centerbox (MIN/AVG/MAX) Yes
Level and span control Manual and auto
Minimum span in auto mode 5 °C
Minimum span in manual mode 2.5 °C
Minimum IR focus distance 15.25 cm (6 in) 1.2 m (4 ft)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade N/A
Minimum automatic parallax correction ~18-22 inches N/A
IR-PhotoNotes annotation system Yes (3 images)
Laser pointer Yes
Torch Yes
Electronic (cardinal) compass Yes
Emissivity correction Yes
Transmission correction Yes
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output Streaming USB video output (infrared, visible and IR-Fusion modes)
Multi-mode video recording (standard avi w/ mpeg encoding) Yes (AVI with MPEG encoding, up to 5 minutes)
Multi-mode video recording (radiometric .Is3) Yes, radiometric .is3 for approx.2.5 to 5 minutes depending upon thermal scene
Memory review thumbnail review
Battery (field-replaceable, rechargeable) Two One
Battery life 4+ hours (each)*
External battery charging base Yes Optional (accessory)
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Recommended Calibration cycle Two-years
Multifunction card reader Included
Memory storage 2 GB SD memory card
Direct download capability mini USB download direct to PC
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, Non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes
*Assumes 50% brightness of LCD



TiR125, TiR110 Thermal Imagers
  Buidling Diagnostics
Images
Model TiR125 TiR110
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 µm to 14 µm (long wave)
Capture or refresh rate 9 Hz
NETD (Thermal sensitivity) ≤0.08 °C at 30 °C target temp (80 mK)
FOV (Field of view) 22.5 °H x 31 °V
IFOV (Spatial resolution) 3.39 mRad
Temperature measurement range (not calibrated below -10 °C) -20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex focus system
IR-Fusion® technology PIP, FULL IR, FULL VISIBLE, AutoBlend PIP, FULL IR, FULL VISIBLE
Color alarms High temperature, low temperature, isotherm High temperature
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Ultra Contrast palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber Blue-Red, Grayscale, Ironbow
Hot/cold markers Yes
User definable spot markers Three on camera and in SmartView
Centerbox (MIN/AVG/MAX) Yes
Level and span control Manual and auto
Minimum span in auto mode 5 °C
Minimum span in manual mode 2.5 °C
Minimum IR focus distance 15.25 cm (6 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade
Minimum automatic parallax correction ~18-22 inches
IR-PhotoNotes annotation system Yes (3 images)
Laser pointer Yes
Torch Yes
Electronic (cardinal) compass Yes
Emissivity correction Yes
Transmission correction Yes
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output Streaming USB video output (infrared, visible and IR-Fusion modes)
Multi-mode video recording (standard avi w/ mpeg encoding) Yes (AVI with MPEG encoding, up to 5 minutes)
Multi-mode video recording (radiometric .Is3) Yes, radiometric .is3 for approx.2.5 to 5 minutes depending upon thermal scene
Memory review thumbnail review
Battery (field-replaceable, rechargeable) Two One
Battery life 4+ hours (each)*
External battery charging base Yes Optional (accessory)
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Recommended Calibration cycle Two-years
Multifunction card reader Included
Memory storage 2 GB SD memory card
Direct download capability mini USB download direct to PC
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, Non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes
*Assumes 50% brightness of LCD



TiS, Ti9, Ti10, Ti25 Thermal Imagers
Images
Model Ti25 Ti10 Ti9 TiS
Detector size 160 x 120 120 x 120
Detector type Uncooled microbolometer, focal plane array
Field of view (FOV) 23º horizontal x 17º vertical 17º horizontal x 17º vertical
Spatial resolution (IFOV) 2.5 mrad
Minimum focus distance 15 cm (approx. 6 in)
Thermal sensitivity (NETD) ≤0.09 °C at 30 °C (90 mK) ≤0.13 °C at 30 °C (130 mK) ≤0.20 °C at 30 °C (200 mK) ≤0.1 °C at 30 °C (100 mK)
Detector data acquisition/###Image frequency 9 Hz
Focus Manual, 1-hand focus
IR digital zoom No
Spectral band 7.5 µm to 14 µm
Transmission correction (On Imager) No
Reflected background temperature correction (On Imager) Yes In software only
Measurement modes
Centerpoint Yes
Center box (area, min/max, average) In software only
User defined spots/boxes In software only  
Advanced on-board analysis functions No
User defined field/text annotations No
Voice annotation Yes No
Automatic hot and cold point detection Yes In software
Image presentation
Digital display 3.6" High Resolution LCD
Video output No
Palettes 6 4 4 3
Optional lenses
Image and data storage
Storage medium SD memory card (2 GB), Stores at lest 1200 fully radiometric (.is2) IR-Fusion images or 3000 basic IR images (.bmp or .jpg)
On imager file formats BMP, IS2
File formats supported in software BMP, JPG, GIF, PNG, TIF, WMF, EXIF and EMF
Imager features
Fully radiometric Yes
Flash and torch light No
Laser pointer No
Windows CE based navigation menu Yes
AutoCapture (Programable Image Capture) No
Software included Yes (SmartView)
Environmental and mechanical design
Operating temperature -10 to +50°C (14 °F to 122 °F)
Storage temperature -20 to +50°C (-4 °F to 122 °F) without batteries
Relative humidity 10% to 90% non-condensing
Water and dust resistant IP54
Weight (including batteries) 1.2 kg (2.65 lb)
Camera size (HxWxD) 0.27 x 0.13 x 0.15 m (10.5 in x 5 in x 5 in)
Warranty 2 years
Power
Battery type NiMH Rechargeable battery pack
Battery operating time 3-4 hours continuous
Battery re-charge time 2 hours for full charge
AC operation (110/220 VAC, 50/60 Hz) Yes
Automatic shut down Yes
Sleep mode Yes
Applications
Electrical distribution/power generation Yes  
In plant electrical Yes No
Electromechanical Yes No
Mechanical systems Yes No
Process monitoring and installations Yes No
Building diagnostics No Yes
Electronics   No
IR-Fusion Technology
IR-Fusion technology Yes No
Full thermal Yes
Full visual light In software No
Auto blending Yes No
Picture in picture Yes No
Color alarm In software only No
Temperature measurement
Temperature range -20 °C to 350 °C in 2 ranges (-4 °F to 662 °F in 2 ranges) -20 °C to 100 °C (-4 °F to 212 °F)
High temperature option No
Accuracy ±2 °C or 2% whichever is greater ±5 °C or 5% whichever is greater
Emissivity correction Yes In software only



Ti27, Ti29, Ti32 Thermal Imagers
Images
Model Ti32 Ti29 Ti27
Detector size 320 x 240 280 x 210 240 x 180
Detector type Uncooled microbolometer, focal plane array
Field of view (FOV) 23º horizontal x 17º vertical
Spatial resolution (IFOV) 1.25 mRad 1.43 mRad 1.67 mRad
Minimum focus distance 15 cm (approx. 6 in)
Thermal sensitivity (NETD) ≤0.045 °C at 30 °C (45 mK) ≤0.05 °C at 30 °C (50 mK ≤0.05 °C at 30 °C (50 mK)
Detector data acquisition/###Image frequency 60 Hz or 9 Hz
Focus Manual, 1-hand focus
IR digital zoom No
Spectral band 7.5 µm to 14 µm
Transmission correction (On Imager) Yes
Reflected background temperature correction (On Imager) Yes
Measurement modes
Centerpoint Yes
Center box (area, min/max, average) In software only
User defined spots/boxes In software only  
Advanced on-board analysis functions No
User defined field/text annotations No
Voice annotation Yes
Automatic hot and cold point detection Yes
Image presentation
Digital display 3.7" LCD
Video output No
Palettes 16 (8 Standard and 8 Ultra Contrast™)
Optional lenses
54 mm Telephoto Yes
10.5 mm Wide angle lens Yes
Image and data storage
Storage medium SD memory card (2 GB), Stores at lest 1200 fully radiometric (.is2) IR-Fusion images or 3000 basic IR images (.bmp or .jpg)
On imager file formats BMP, JPG, IS2
File formats supported in software BMP, JPG, GIF, PNG, TIF, DIB, JPE, JFIF, JPEG, TIFF
Imager features
Fully radiometric Yes
Flash and torch light No
Laser pointer No
Windows CE based navigation menu Yes
AutoCapture (Programable Image Capture) No
180º articulating lens No
Software included Yes (SmartView)
Environmental and mechanical design
Operating temperature -10 to +50°C (14 °F to 122 °F)
Storage temperature -20 to +50°C (-4 °F to 122 °F) without batteries
Relative humidity 10% to 90% non-condensing
Water and dust resistant IP54
Weight (including batteries) 1.05 kg (2.3 lb) battery included
Camera size (HxWxD) 277 x 122 x 170 mm (10.9 in x 4.8 in x 6.7 in)
Warranty 2 years
Power
Battery type Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
Battery operating time 4+ hours continuous per battery pack
Battery re-charge time 2.5 Hours or less to full charge
AC operation (110/220 VAC, 50/60 Hz) Yes
Automatic shut down Yes
Sleep mode Yes
Applications
Electrical distribution/power generation Yes
In plant electrical Yes
Electromechanical Yes
Mechanical systems Yes
Process monitoring and installations Yes
Other Yes
IR-Fusion Technology
IR-Fusion technology Yes
Full thermal Yes
Full visual light In software
Auto blending Yes
Picture in picture Yes
Color alarm Yes (High temperature)
Temperature measurement
Temperature range -20 °C to 600 °C (-4 °F to 1112 °F)
High temperature option No
Accuracy ±2 °C or 2% whichever is greater
Emissivity correction Yes



TiR, TiR1, TiR27 Thermal Imagers
Images
Model TiR27 TiR1 TiR
Detector size 240 x 180 160 x 120 160 x 120
Detector type Uncooled microbolometer, focal plane array
Field of view (FOV) 23º horizontal x 17º vertical
Spatial resolution (IFOV) 1.67 mRad 2.5 mrad 2.5 mrad
Minimum focus distance 15 cm (approx. 6 in)
Thermal sensitivity (NETD) ≤0.045 °C at 30 °C (45 mK) ≤0.07 °C at 30 °C (70 mK) ≤0.9 °C at 30 °C (90 mK)
Detector data acquisition/###Image frequency 60 Hz or 9 Hz 9 Hz 9 Hz
Focus Manual, 1-hand focus
IR digital zoom No
Spectral band 7.5 µm to 14 µm
Transmission correction (On Imager) Yes
Reflected background temperature correction (On Imager) Yes In software only
Measurement modes
Centerpoint Yes
Center box (area, min/max, average) In software only
User defined spots/boxes In software only  
Advanced on-board analysis functions No
User defined field/text annotations No
Voice annotation Yes No
Automatic hot and cold point detection Yes In software
Image presentation
Digital display 3.7" LCD 3.6" High Resolution LCD 3.6" High Resolution LCD
Video output No
Palettes 16 (8 Standard and 8 Ultra Contrast™) 6 4
Optional lenses
54 mm Telephoto Yes  
10.5 mm Wide angle lens Yes  
Image and data storage
Storage medium SD memory card (2 GB), Stores at lest 1200 fully radiometric (.is2) IR-Fusion images or 3000 basic IR images (.bmp or .jpg)
On imager file formats BMP, JPG, IS2
File formats supported in software BMP, JPG, GIF, PNG, TIF, DIB, JPE, JFIF, JPEG, TIFF
Imager features
Fully radiometric Yes
Flash and torch light No
Laser pointer No
Windows CE based navigation menu Yes
AutoCapture (Programable Image Capture) No
180º articulating lens No  
Software included Yes (SmartView)
Environmental and mechanical design
Operating temperature -10 to +50°C (14 °F to 122 °F)
Storage temperature -20 to +50°C (-4 °F to 122 °F) without batteries
Relative humidity 10% to 90% non-condensing
Water and dust resistant IP54
Weight (including batteries) 1.05 kg (2.3 lb) battery included 1.2 kg (2.65 lb) 1.2 kg (2.65 lb)
Camera size (HxWxD) 277 x 122 x 170 mm (10.9 in x 4.8 in x 6.7 in) 0.27 x 0.13 x 0.15 m (10.5 in x 5 in x 5 in) 0.27 x 0.13 x 0.15 m (10.5 in x 5 in x 5 in)
Warranty 2 years
Power
Battery type Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level NiMH Rechargeable battery pack
Battery operating time 4+ hours continuous per battery pack 3-4 hours continuous
Battery re-charge time 2.5 Hours or less to full charge 2 hours for full charge
AC operation (110/220 VAC, 50/60 Hz) Yes
Automatic shut down Yes
Sleep mode Yes
Applications
In plant electrical Light electrical No
Electromechanical Light electomechanical No
Mechanical systems Light mechanical No
Process monitoring and installations   No
Building diagnostics Yes
Electronics   No
Other Yes  
IR-Fusion Technology
IR-Fusion technology Yes
Full thermal Yes
Full visual light In software
Auto blending Yes
Picture in picture Yes
Color alarm Yes (Dew Point) Yes (Dew Point)
Temperature measurement
Temperature range -20 °C to 600 °C (-4 °F to 1112 °F)
High temperature option No
Accuracy ±2 °C or 2% whichever is greater
Emissivity correction Yes In software only



TiR29, TiR32 Thermal Imagers
Images
Model TiR32 TiR29
Detector size 240 x 180 280 x 210
Detector type Uncooled microbolometer, focal plane array
Field of view (FOV) 23º horizontal x 17º vertical
Spatial resolution (IFOV) 1.25 mRad 1.43 mRad
Minimum focus distance 15 cm (approx. 6 in)
Thermal sensitivity (NETD) ≤0.040 °C at 30 °C (40 mK) ≤0.045 °C at 30 °C (45 mK)
Detector data acquisition/###Image frequency 60 Hz or 9 Hz
Focus Manual, 1-handed SmartFocus
IR digital zoom No
Spectral band 7.5 µm to 14 µm
Transmission correction (On Imager) Yes
Reflected background temperature correction (On Imager) Yes
Measurement modes
Centerpoint Yes
Center box (area, min/max, average) In software only
User defined spots/boxes In software only  
Advanced on-board analysis functions No
User defined field/text annotations No
Voice annotation Yes
Automatic hot and cold point detection Yes
Image presentation
Digital display 3.7" LCD
Video output No
Palettes 16 (8 Standard and 8 Ultra Contrast™)
Optional lenses
54 mm Telephoto Yes
10.5 mm Wide angle lens Yes
Image and data storage
Storage medium SD memory card (2 GB), Stores at lest 1200 fully radiometric (.is2) IR-Fusion images or 3000 basic IR images (.bmp or .jpg)
On imager file formats BMP, JPG, IS2
File formats supported in software BMP, JPG, GIF, PNG, TIF, DIB, JPE, JFIF, JPEG, TIFF
Imager features
Fully radiometric Yes
Flash and torch light No
Laser pointer No
Windows CE based navigation menu Yes
AutoCapture (Programable Image Capture) No
180º articulating lens No
Software included Yes (SmartView)
Environmental and mechanical design
Operating temperature -10 to +50°C (14 °F to 122 °F)
Storage temperature -20 to +50°C (-4 °F to 122 °F) without batteries
Relative humidity 10% to 95% non-condensing
Water and dust resistant IP54
Weight (including batteries) 1.05 kg (2.3 lb) battery include
Camera size (HxWxD) 277 x 122 x 170 mm (10.9 in x 4.8 in x 6.7 in)
Warranty 2 years
Power
Battery type Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
Battery operating time 4+ hours continuous per battery pack
Battery re-charge time 2.5 Hours or less to full charge
AC operation (110/220 VAC, 50/60 Hz) Yes
Automatic shut down Yes
Sleep mode Yes
Applications
In plant electrical Light electrical
Electromechanical Light electomechanical
Mechanical systems Light mechanical
Building diagnostics Yes
Other Yes
IR-Fusion Technology
IR-Fusion technology Yes
Full thermal Yes
Full visual light In software
Auto blending Yes
Picture in picture Yes
Color alarm Yes (Dew Point) Yes (Dew Point)
Temperature measurement
Temperature range -20 °C to 600 °C (-4 °F to 1112 °F)
High temperature option No
Accuracy ±2 °C or 2% whichever is greater
Emissivity correction Yes



Ti55FT, Ti50FT, Ti45FT, Ti40FT Thermal Imagers
Images
Features Ti55FT Ti50FT Ti45FT Ti40FT
High resolution, low noise VOx detector for high quality images 320 x 240 160 x 120
Temperature range to cover broad industrial applications -20 to +600 ºC (-4 to 1112 ºF) -20 to +350 ºC(-4 to 662 ºF) -20 to + 600 ° C (-4 to 1112 °F)
High thermal sensitivity for viewing even the smallest temperature differences ≤ 0.05 ºC ≤ 0.07 ºC ≤ 0.08 ºC (80 mK) ≤ 0.09 ºC (90 MK)
180º articulating flexible lens to view images in every situation
Choice of 3 interchangeable lenses to cover every application
Large 5" high contrast color LCD for a clear picture independent of lighting conditions
Fully radiometric for detailed temperature analysis and tracking
SmartFocus for best image quality and accurate temperature measurements
Windows® CE based menu structure for ease of use
Personalized instrument set-up for multiple use
CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data
SmartView reporting and analysis software included
AutoCapture for making intermittent problems visible  
On-board analysis functions  
User defined text annotations for simplified reporting  
Built-in visible light (digital) camera
IR/Visible Alarm function    
Laser pointer for easy targeting
Flash and torch light for high quality images in dark environments



TiR4FT, TiR3FT, TiR2FT Thermal Imagers
Images
Features TiR4FT TiR3FT TiR2FT
High-Resolution, Low Noise VOx Detector 320 x 240 160 x 120
Temperature Range -20 to +100°C
High Thermal Sensitivity ≤ 0.05 °C ≤ 0.07 °C
180° Articulating Flexible Lens
Interchangeable Lenses
3.6" Color LCD      
5" Color LCD
Radiometric
SmartFocus
Windows CE Based Menu Structure
Multiple User Profiles
CompactFlash memory Cards
SD memory Cards      
SmartView Software Included
AutoCapture  
On-board Analysis Functions  
User Defined Test Annotations  
Built-in Visible Light (Digital) Camera
IR-Fusion
IR/Visible Alarm Function
Laser Pointer
Flash and Torchlight
Imaging performance
Field of view (FOV)* 23° horizontal x 17° vertical
Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad
Minimum focus distance* 0.15 m
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C ≤ 0.07 °C at 30 °C
Detector data acquisition / Image frequency 60 Hz 30 Hz
Focus SmartFocus; one finger continuous focus
IR digital zoom 2x, 4x, 8x 2x
Detector type Focal Plane Array (FPA) Uncooled Microbolometer
Detector size 320 x 240 FPA 160 x 120 FPA
Spectral band 8 µm to 14 µm 160 x 120 FPA
Digital image enhancement Automatic full-time enhanced
Imaging Performance - Visual
On camera operating modes Full thermal, full visual light or merged thermal-visual images. Picture-in-picture. Alarm.
Visible light camera 1280 x 1024 pixels, full color (1.3 Mega pixel)
Visible light digital zoom 2x, 4x 2x
Temperature Measurement
Calibrated temperature range -20 °C to 100 °C (-4 °F to 212 °F)
Accuracy ± 2 °C or 2 % (whichever is greater)
Measurement modes Centerpoint, center box (area min/max, average) moveable spot Centerpoint, center box (area min/max, average) Centerpoint, center box (area min/max, average) moveable spot
Emissivity correction 0.1 to 1.0 (0.01 increments)
Image Presentation
Digital display 5” large high-resolution digital display
LCD backlight Sunlight readable color LCD
Video output RS170 EIA/NTSC or CCIR/PAL composite video
Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, iron
Optional Lens
10.5 mm wide-angle lens High precision Germanium lens
Field of view (FOV) 42° horizontal x 32° vertical
Spatial resolution (IFOV) 2.45 mrad 4.9 mrad
Minimum focus distance 0.3 m
Image & Data Storage
Storage medium Compact flash card stores more than 1000 IR images (512 MB card standard)
File formats supported 14 bit measurement data included. Exportable BMP, GIF, JPEG, PNG, TIFF
Interfaces & Software
Interface Compact flash card reader included
Software SmartView; full analysis and reporting software included
Laser
Classification Class II
Laser targeting Laser dot visible on screen when blending thermal and visible image
Controls & Adjustments
Set-up controls Date/time, temperature units C/F, language, calibration range, LCD intensity (high/normal/low)
Image controls Level, span, auto adjust, emissivity and background (continuous/manual)
On-screen indicators Battery status, target emissivity, background temperature and realtime clock
Power
Battery type Li-Ion smart battery, rechargeable, field-replaceable
Battery operating time Two hours continuous operation
Battery charging 2 bay intelligent charger powered via AC outlet
AC operation AC adapter 110/220 VAC, 50/60 Hz (TiR2FT/TiR4FT only)
Power saving Automatic shutdown and sleep modes (user specified)
DC operation Vehicle 12 volt adaptor optional
Environmental & Mechanical Design
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -40 °C to +70 °C (-40 °F to 158 °F)
Relative humidity Operating and storage 10 % to 95 %, non-condensing
Water and dust resistant IP54
Weight (including batteries) 1.95 kg (4.29 pounds)
Camera size (HxWxD) 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in)
Other
Warranty Two-years
X