Fluke 16 Digital Multimeter with Thermometer
| DC Volts Specifications |
| Range 4000 mV * |
Resolution: 1 mV
Accuracy: 0.9% + 2 |
| Range 4.000 V |
Resolution: 0.001 V
Accuracy: 0.9% + 2 |
| Range 40.00 V |
Resolution: 0.01 V
Accuracy: 0.9% + 1 |
| Range 400.0 V |
Resolution: 0.1 V
Accuracy: 0.9% + 1 |
| Range 600 V |
Resolution: 1 V
Accuracy: 0.9% + 1 |
*The 4000 mV range can only be entered in manual range mode.
Use the 4000 mV range with accessories.
| AC Volts Specifications |
| Range 4000 mV * |
Resolution: 1 mV
Accuracy: 1.9% + 3 |
| Range 4.000 V |
Resolution: 0.001 V
Accuracy: 1.9% + 3 |
| Range 40.00 V |
Resolution: 0.01 V
Accuracy: 1.9% + 3 |
| Range 400.0 V |
Resolution: 0.1 V
Accuracy: 1.9% + 3 |
| Range 600 V |
Resolution: 1 V
Accuracy: 1.9% + 3 |
*The 4000 mV range can only be entered in manual range mode.
Use the 4000 mV range with accessories.
| Current (AC/DC) Specifications |
| Range 200 µA |
Resolution: 0.1 µA
Accuracy: 0.5% + 2 |
| Ohms Specifications |
| Range 400.0 W |
Resolution: 0.1 W
Accuracy: 0.9% + 2 |
| Range 4.000 KW |
Resolution: 0.001 KW
Accuracy: 0.9 % + 1 |
| Range 40.00 KW |
Resolution: 0.01 KW
Accuracy: 0.9% + 1 |
| Range 400.0 KW |
Resolution: 0.1 KW
Accuracy: 0.9% +1 |
| Range 4.000 MW |
Resolution: 0.001 MW
Accuracy: 0.9% +1 |
| Range 40.00 MW |
Resolution: 0.01 MW
Accuracy: 1.5% +3 |
| Capacitance Specifications * |
| Range 1.000 µF |
Resolution: 0.001 µF
Accuracy: 1.9% + 2 |
| Range 10.00 µF |
Resolution: 0.01 µF
Accuracy: 1.9% + 2 |
| Range 100.0 µF |
Resolution: 0.1 µF
Accuracy: 1.9% + 2 |
| Range 1000 µF |
Resolution: 1.0 µF
Accuracy: 1.9% + 2 |
| Range 10,000 µF |
Resolution: 10.0 µF
Accuracy: 10% + 90 typical |
*The accuracy specification is for capacitors that have negligible dielectric absorption. Capacitance measured with rc charge technique that evaluates C = Q/V. Capacitors with non-negligible dielectric absorption can be measured but measurement values may be in error.
| Temperature Specifications * |
| Range 15 to 750 °F |
Resolution: 0.1 °F
Accuracy: 1% + 1.5 °F typical |
| Range -40 to 15 °F |
Resolution: 0.1 °F
Accuracy: 5% + 2.7 °F |
| Range -10 to 400 °C |
Resolution: 0.1 °C
Accuracy: 1% + 0.8 °C typical |
| Range -40 to 10 °C |
Resolution: 0.1 °C
Accuracy: 5% + 1.5 °C |
*Temperature accuracy specifications do not include the error of the thermocouple.
| Safety |
| 600V ac/dc |
Maximum voltage between any terminal and earth ground. Conforms to the requirements of IEC-1010-1, 1990-09 and ANSI/ISA-S82.01-94 for use in Overvoltage Category III locations. Make ac or dc voltage measurements on electrical distribution systems to 600V where transients do not exceed 6 kV and only on circuits limited to 14 kVA if the circuit voltage rating is above 250V. |
| Certification agencies (approvals/listings pending) |
UL Per standard UL 3111
CSA Per standard CSA/CAN C22.2 No.1010.1-92
TsV Per standard EN61010 Part 1-1993 |
| Drop test |
ANSI/ISA-S82.01-94 and EN61010 Part1-1993. 10 ft. drop to hardwood on concrete |
| General Specifications |
| Size |
(HxWxL) 1.12" x 2.95" x 6.55", (2.8 cm x 7.5 cm x 16.6 cm) |
| Battery life |
650 hours with Alkaline |
| Weight |
12 oz (340g) |
| Warranty |
Three years |
|