Bacharach 0077-7072 Model DD5 Detroit Diesel Injector Calibrator Bacharach 0077-7072, 00777072, 0077 7072
company logo Bacharach 0077-7072 Model DD5
Detroit Diesel Injector Calibrator
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Bacharach 0077-7072 Model DD5
Detroit Diesel Injector Calibrator




Click image to enlarge

 0077-7072

Datasheet
User Manual

Features:
  • 5 HP Electric Drive Motor
  • Digital fuel delivery measurement
  • Floor Standing Unit; full welded frame construction
  • Operating speed 2000 rpm
  • Cast Iron Cambox with tapered roller bearings and quick change cam capability
  • Injector Clamping: hydraulic, with mechanical lock
  • Calibration fluid reservoir capacity: 8 U.S. Gallons (30 liters)




  Description

Detroit Diesel Injector Calibrator Model DD5

The Bacharach Calibrator DD5 provides the diesel fuel injection specialist with a fast, safe and extremely accurate means of calibrating Detroit Diesel mechanical injectors (MUI) in accordance with the manufacturer’s instructions.




  Models, Options, & Accessories


Model Description List Price Sale Price
0077-7072 Please call or email us for pricing and availability.
0077-7073 Please call or email us for pricing and availability.
0077-7074 Please call or email us for pricing and availability.
0077-7075 Please call or email us for pricing and availability.
0077-7076 Please call or email us for pricing and availability.



  Specifications

Filtration: Primary filter (spin-on type): 10 micron
Final stage filter (spin-on type): 3 micron
Flowmeter transducer: Screen
Calibration fluid temperature control: Solid state control
100 ±1 °F (factory setting)
Cooling by cold tap water
Heating by two 500 watt immersed electric heaters
Instrumentation & Controls: Injector Supply (Rail) Pressure Gauge, 4" dial, 0-100 psi
Calibration Fluid Temperature Gauge, dual scale: 40-140 °F (5-60 °C)
Supply Pressure Regulator
Clamping Pressure Regulator
Main Drive Start/Stop Switch
Measurement System Start Switch
Measurement System: Positive Displacement Flowmeter (U.S. patent No. 4141243)
Measurement Units: mm3/str.
Digital display resolution: 0.1 mm3/str.
Measurement period: 100 strokes
Stroke counter: electronic/optical
Accuracy: ±0.75% of reading, or 1 mm3/str., whichever is greater
Indicator Lights: Power (red)
Heat/Cool (amber)
Clamping (amber)
Accessibility: Two front and one upper-left hand side hinged doors. All other panels have quick turn fasteners for easy removal.
Dimensions: 50" W x 30" D x 56" H (1.27 x 0.76 x 1.42 m)
Weight (dry): 1150 lbs (522 kg)
Utilities Required: Power Supply: 230 VAC, 3 Phase, 60 Hz, 30 Amps (standard). Other voltages/frequencies available.
Air Pressure: 80-120 psi (2 CFM)
Water: Cold tap, approx. 1.2 GPM (4.5 liter/min)
Accessories: All the required accessories are included for mounting and testing Detroit Diesel 53, 71, 92, 149 and 8.2L Mechanical Unit Injectors.
Provision for hanging all accessories on pegboard inside front door




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.