Features:
  • Large, easy-to-read fluorescent display that is visible from wide angles.
  • Battery life of over eight hours.
  • Modular design lets you add sensors as your needs change.
  • Built-in printer and complete data downloading to a PC capability.
  • EPA-ETV test verified performance.
  • Measures and displays O2 and CO in the flue gas, pressure (draft), primary air temperature, and stack temperature.
  • Calculates and displays combustion efficiency, excess air, and CO2.
  • Optionally measures and displays NO, NO2, SO2, HC (methane equivalent combustibles), and CO in the high range of 4,000 to 80,000 ppm).
  • Optionally calculates NOx (the combination of NO and NO2), and calculates CO, SO2, and NOx individually referenced to a user defined Oxygen level of between 0 and 15%.
  • Optionally displays pollution conversions for CO, NO, NO2, and SO2. Pollution conversions include parts per million, pounds of pollutant per million BTU, milligrams of pollutant per cubic meter of gas, and grams of pollutant per gigajoule.
  • Stores over 1000 individual combustion and/or pressure test records, which can later be recalled for viewing or printing.
  • Stored test records can be downloaded to a personal computer and stored as a text file, which can then be opened in a spreadsheet program for analysis.
  • Performs datalogging.



  Description

ECA 450 Combustion Efficiency & Environmental Analyzer

The ECA 450 is ideal for professionals concerned about combustion efficiency, environmental compliance, or both. It enables plant maintenance engineers and managers, industrial boiler/furnace service technicians, energy coordinators, compliance officers, environmental auditors and safety managers ensure that industrial equipment is burning efficiently while environmental regulations are being met:

  • Plant maintenance engineers or managers
  • Industrial boiler/furnace service technicians
  • Energy coordinators
  • Compliance officers
  • Environmental auditors
  • Safety managers

Unlike any other industrial grade combustion efficiency and environmental analyzer on the market today, the new ECA 450 from Bacharach conducts accurate combustion and emissions tests that will help you meet environmental regulations and ensure your equipment is burning efficiently. The ECA 450 measures Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide and Sulfur Dioxide, as well as combustibles, temperature and draft. It also calculates combustion efficiency, excess air, carbon dioxide, NOx (Nitrogen Oxides) and pollution units.

The ECA takes continuous samplings of furnaces, boilers and other industrial combustion equipment for up to eight hours and generates precise, reliable combustion and environmental measurements and calculations. And it generates this complex data easily - even at selected intervals - enabling plants to make more accurate equipment adjustments and better assess pollution levels. The ECA 450 helps improve overall combustion efficiency, reduce fuel costs, and determine emissions compliance.

Easy Operation

The ECA 450 is a microprocessor-based instrument with front panel controls. It’s menu driven, but also provides access to any major display screen with just one front panel button push. To facilitate this, Fuel, Pressure, Memory, Setup and Calibration have dedicated buttons. So, no matter where you are in the menu structure, you can access these features simply by pressing a button. Plus, you can set the instrument to be completely customized to your liking. You can get the data you need in a format you want with just a few simple button pushes.

Large, Easy-To-Read Data Display

Test data is presented on a large vacuum fluorescent display that is incredibly easy to view from any angle. All measured and calculated data are updated simultaneously and can be reviewed by simply scrolling down a list.

Customized Setups

You have the ability to set up your ECA 450 so it provides information in a format that is most convenient for you. A menu guides you through a few simple front panel button pushes that tell the unit what information you want and how you want it displayed. Examples of some of the custom set-ups offered by the ECA 450 include:

  • Selectable temperature units (C or F)
  • Selectable pressure units (inches, H2O, mb, Pa, hPa)
  • Selectable language (English, French, Spanish)
  • Selectable pollution units (ppm, Lb/Mbtu, mg/m3, g/GJ)
  • Data display order
  • Keypad sound

In addition, both customer information and user information can be cataloged and tracked. This allows you to store test data by customer and keep a running history of it. And at the same time, you can customize customer data print outs with your own company name, address and phone number.

User Selectable Fuels

Once the ECA 450 has gone through its warm-up cycle, you can begin to perform tests for any of 10 selectable fuels. You select the fuel, and the instrument will make calculations based on that fuel until another fuel is selected.

Outstanding Performance

According to the 2000 EPA/ETV Joint Verification Statement, the ECA 450 offers consistent, reliable test results for NOX.

"The verification test indicates that the performance of the two Bacharach ECA 450 analyzers was essentially identical in all respects. Unit-to-unit agreement for NOX from combustion sources was 1.1 to 4.6% and was, in some cases, better than that of the two reference analyzers."

- Quoted from the 2000 EPA/ETV Joint Verification Statement

Software Calibration

Calibration adjustments can be made on an as-needed basis, in the field, with a few simple front panel button pushes. Potentiometer adjustment is not required. The calibration mode is password protected so that after the correct password is entered, you can calibrate any combination of the measuring channels. If the calibration is unsuccessful, the instrument will inform you that an improper calibration has been performed and the new settings will not be accepted. The ECA 450 also automatically zeros all sensing channels on ambient air when the instrument is turned on. If a particular sensor is in error during warm-up, the instrument will automatically warn you that a problem exists. Calibration is still recommended every six months - or sooner if necessary. To arrange for this service to be performed in-factory, just place a quick call to Bacharach.

Sensor Maintenance

We’ve designed the ECA 450 so that sensors could be replaced in the field as well. Easy access to the sensor housing is provided through the front panel of the instrument. Most sensors can be removed simply by twisting them out of their bayonet housing. Also, sensor life can be improved by regularly replacing sensor filters.

Memory

The ECA 450 has the ability to save up to 1,000 test records in memory. Test records are time and date coded for easy recognition. You can also create information tags that can be attached to the data as it is saved to memory.

Data Logging

The ECA 450 also has the ability to log data by interval and duration. The instrument will automatically save records until memory is full.

Printing

The ECA 450 can print individual test records, in real time or from memory, to an internal printer.

Downloading

The ECA 450 lets you download test data to your personal computer so that you can develop spreadsheet programs.

Additional Images:

                               

Click images to enlarge



  Models, Options, & Accessories


Model Description List Price Sale Price
0024-7221 ECA 450 BASE UNIT (02, CO) W/PROBE $6175.00
$5866.25 
0024-7289 ECA 450 BASE UNIT W/PROBE & WIRELESS REMOTE $9220.00
$8759.00 
Model Accessories List Price Sale Price
0024-7223 HEAVY DUTY SAMPLE CONDITIONER $9995.00
$9495.25 
0024-7224 Compact Sample Conditioner $2000.00
$1900.00 
0024-0788 REPLACEMENT 02 SENSOR, PCA & ECA $159.00
$151.05 
0024-0789 REPLACEMENT CO SENSOR, PCA & ECA $320.00
$304.00 
0024-0997 REPLACEMENT CO SENSOR (HIGH), ECA $320.00
$304.00 
0024-0881 REPLACEMENT NO SENSOR, PCA & ECA $320.00
$304.00 
0024-1055 REPLACEMENT COMBUSTIBLES SENSOR, ECA $210.00
$199.50 
0024-1027 REPLACEMENT NO2 SENSOR FOR ECA 450 $320.00
$304.00 
0024-0998 REPLACEMENT SO2 SENSOR FOR ECA $320.00
$304.00 
0024-1124 PROBE HOSE EXTENSION 20 FT, PCA, PCA 2 & ECA $410.00
$389.50 
0024-3024 24" PROBE ASSY, ECA $545.00
$517.75 
0024-3025 36" PROBE ASSY, ECA $580.00
$551.00 
0007-1644 FILTER, SHORT WHITE (PACKAGE OF 3) $30.00
$28.50 
0024-7059 PORTABLE CALIBRATION KIT $305.00
$289.75 
0104-1800 THERMOCOUPLE EXTENSION CABLE $78.00
$74.10 
0104-4027 SERIAL CABLE $65.00
$61.75 
0024-0980 PRINTER PAPER, ECA (PKG OF 5 ROLLS) $26.00
$24.70 
0024-8400 ECA 450 NOX KIT W/SAMPLE COND. $9015.00
$8564.25 
0024-8401 ECA 450 NOX & SOX KIT W/SAMPLE COND. $9655.00
$9172.25 



  Specifications

Measured Data
Oxygen 0.1 to 20.9%
Carbon Monoxide
(hydrogen compensated)
0 to 4000 ppm
Carbon Monoxide High 4001 to 80,000 ppm
Nitric Oxide* 0 to 3500 ppm
Nitrogen Dioxide* 0 to 500 ppm
Sulfur Dioxide* 0 to 4000 ppm
Combustibles* 0 to 5% (application dependent)
Stack Temp. -4 to 2400°F (-20 to 1315°C)
Primary/Ambient Temp. -4 to 999°F (-20 to 999°C)
Pressure/Draft -27.7 to 27.7 inches of Water
Calculated Data
Combustion Efficiency 0.1 to 100.0%
Excess Air 1.0 to 250%
Carbon Dioxide
(dry basis)
0 to fuel dependent maximum
NOx 0 to 4000 ppm
NOx (ref. to %O2) 0 to 17,000 ppm
CO (ref. to %O2) 0 to 99,9999 ppm
NO (ref. to %O2) 0 to 14,900 ppm
NO2 (ref. to %O2) 0 to 2100 ppm
SO2 (ref. to %O2) 0 to 17,000 ppm
Miscellaneous
Power Universal AC adapter and an internal battery pack. Adapter will accept input voltages from 100 to 240V. Fully charged battery pack provides a minimum of 8 hours of operation
Pumps & Probe Two pumps are included. The first pump supplies gas sample to the sensors. The second pump supplies fresh air to purge the low-range CO sensor when CO levels exceed 400 ppm. Probe includes a standard probe and hose assembly equipped with a water trap, particulate filter, probe stop, 15 feet of hose, and 12-inch probe tube
Size 13.5"H x 18.5"W x 9"D (342.9 x 467.0 x 228.6 mm)
Weight 25 lbs (11.34 kg)
Warranty 1 year, extended warranty available
    *Optional



 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.