Agilent 6611C 40 Watt System Power Supply

Click image to enlarge
Agilent 6611C
|
|
Features:
- High throughput
- Precision low current measurement
- Low-output noise
- High-speed programming
- GPIB and RS-232 interface
- SCPI (Standard Commands for Programmable Instruments)
- VXI plug&play drivers
Warranty:
1 year
|
Description
The Agilent 6611C System dc Power Supply is an ideal power source for demanding production test applications. This dc power supply offers high performance and precision measurements in a one-box solution. To reduce test-system development time and provide precision testing, the 6611C provides current measurement down to the microamp level. The 6611C also provides high-speed programming with under 4 millisecond response time.
This series of linear-regulated 40-50 W dc power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast programming and measurement, and also active downprogramming. It offers many advanced programmable features including stored states and status reporting. Programming is done using industry standard SCPI commands via the GPIB or RS-232. Test system integration is further simplified by using the VXIPlug&Play drivers. The optional relays simplify system design and troubleshooting.
The half-rack size of the 6610A series makes it a convenient dc power supply for the R&D lab bench. The built-in microamp measurement system helps the engineer to easily and accurately monitor the output voltage and current without a complicated test setup.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 6611C |
DC power supply, 0-8 V, 0-5 A, 40 W. GPIB, RS-232. |
| $2356.20 |  |
|
| 6612C |
DC power supply, 0-20 V, 0-2 A, 40 W. GPIB, RS-232. |
| $2356.20 |  |
|
| 6613C |
DC power supply, 0-50 V, 0-1 A, 50 W. GPIB, RS-232. |
| $2356.20 |  |
|
| 6614C |
DC power supply, 0-100 V, 0-0.5 A, 50 W. GPIB, RS-232. |
| $2356.20 |  |
|
| 6611C-J0C |
Please call or email us for pricing and availability. |
| Model |
Options |
List Price |
Sale Price |
| 6611C-1CM |
Rackmount kit (p/n 5062-3972) includes blank filler panel |
| $73.68 |  |
|
| 6611C-760 |
DC isolation and polarity reversal relay |
| $222.60 |  |
|
| 6611C-A6J |
ANSI/NCSL Z540 calibration certificate |
| $373.80 |  |
|
| 6611C-AXS |
Rackmount kit for side by side mounting (p/n 5062-3974, p/n 5061-9694) |
| $97.06 |  |
|
| 6611C-J05 |
Voltage increased to 10V, current remains 0-5A. AC input 60Hz and 120Vac and 220Vac ranges ONLY |
| $602.70 |  |
|
| 6611C-UK6 |
Commercial calibration with test results data |
| $157.50 |  |
|
Specifications
(at 0º to 55ºC unless otherwise specified)
Supplemental characteristics
| |
6611C |
6612C |
6613C |
6614C |
6611C-J05 |
| Number of outputs |
1 |
1 |
1 |
1 |
1 |
| GPIB |
Yes |
Yes |
Yes |
Yes |
Yes |
| Output Ratings |
| Voltage |
0 to 8 V |
0 to 20 V |
0 to 50 V |
0 to 100 V |
0 to 10 V |
| Current |
0 to 5 A |
0 to 2 A |
0 to 1 A |
0 to 0.5 A |
0 to 5 A |
| Programming accuracy (at 25ºC ±5ºC) |
| Voltage |
5 m V |
10 m V |
20 m V |
50 m V |
5 m V |
| +Current |
0.05% + |
2 m A |
1 m A |
0.75 m A |
0.5 m A |
2 m A |
| Ripple and noise 20 Hz to 20 MHz, with outputs ungrounded or with either terminal grounded |
| Voltage |
rms |
0.5 mV |
0.5 mV |
0.5 mV |
0.5 mV |
0.5 mV |
| peak -to-peak |
3 mV |
3 mV |
4 mV |
5 mV |
3 mV |
| Normal mode |
rms |
2 mA |
1 mA |
1 mA |
1 mA |
2 mA |
| dc measurement accuracy via GPIB or front-panel meters respect to actual outputat 25ºC ±5ºC |
| Voltage |
0.03% + |
2 mV |
3 mV |
6 mV |
12 mV |
2 mV |
| Low current range |
-20 mA to +20 mA |
0.1% + |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
2.5 μA |
| High current range |
+20 mA to + rated 1 |
0.2% + |
0.5 mA |
0.25 mA |
0.2 mA |
0.1 mA |
0.5 mA |
| -20 mA to - rated 1 |
0.2% + |
1.1 mA |
0.85 mA |
0.8 mA |
0.7 mA |
1.1 mA |
| Load regulation |
| Voltage |
2 mV |
2 mV |
4 mV |
5 mV |
2 mV |
| Current |
1 mA |
0.5 mA |
0.5 mA |
0.5 mA |
1 mA |
| Line regulation |
| Voltage |
0.5 mV |
0.5 mV |
1 mV |
1 mV |
0.5 mV |
| Current |
0.5 mA |
0.5 mA |
0.25 mA |
0.25 mA |
0.5 mA |
| Transient response time |