Agilent 66101A 8V Power Module

Click image to enlarge
Agilent 66101A
|
|
Features:
- Output sequencing
- Low ripple and noise
- High-accuracy read-back of voltage and current over GPIB
- Standard Commands for Programmable Instruments (SCPI)
- VXI plug&play drivers
- Optional keyboard and display unit
- Built-in self-test
|
Description
|
The Agilent 66101A power system simplifies test-system assembly, cabling programming, debugging, and operation. It is ideal for ATE and production test environments, where it can supply bias power and stimulus to subassemblies and final products. The Agilent modular power system saves rack space. The 66000A 7-in high (4-EIA units) mainframe can accommodate up to eight dc power modules.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 66000A |
Modular Power System Mainframe - 8 slots, GP-IB |
| $2319.00 |  |
|
| 66101A |
DC power module - 8 V, 16 A, 128 W |
| $2130.00 |  |
|
| 66102A |
DC power module - 20 V, 7.5 A, 150 W |
| $2130.00 |  |
|
| 66103A |
DC power module - 35 V, 4.5 A, 157 W |
| $2130.00 |  |
|
| 66104A |
DC power module - 60 V, 2.5 A, 150 W |
| $2130.00 |  |
|
| 66105A |
DC power module - 120V, 1.25A, 150W |
| $2130.00 |  |
|
| 66106A |
DC power module - 200V, 0.75A, 150W |
| $2130.00 |  |
|
| Model |
Options |
List Price |
Sale Price |
| 66101A-760 |
Add isolation/polarity relays |
| $209.00 |  |
|
| 66101A-A6J |
ANSI/NCSL Z540 calibration certificate |
| $319.00 |  |
|
| 66101A-J03 |
Output modified - 5.7V, 20A, 114W |
| $306.00 |  |
|
| 66101A-J05 |
Output modified - 12V, 12A, 144W |
| $306.00 |  |
|
| 66101A-J10 |
Two fault indicators in module |
| $123.00 |  |
|
| 66101A-J17 |
Provides external Imonitor |
| $390.00 |  |
|
| 66101A-UK6 |
Commercial calibration with test results data |
| $146.00 |  |
|
Specifications
(at 0º to 55ºC unless otherwise specified)
Supplemental characteristics
| |
66101A |
66102A |
66103A |
66104A |
66105A |
66106A |
| Output ratings at 40ºC |
| Output voltage |
0 to 8 V |
0 to 20 V |
0 to 35 V |
0 to 60 V |
0 to 120 V |
0 to 200 V |
| Output current |
0 to 16 A |
0 to 7.5 A |
0 to 4.5 A |
0 to 2.5 A |
0 to 1.25 A |
0 to 0.75 A |
| Maximum power |
128 W |
150 W |
150 W |
150 W |
150 W |
150 W |
| Programming accuracy at 25ºC ±5ºC |
| Voltage |
0.03% + |
3 mV |
8 mV |
13 mV |
27 mV |
54 mV |
90 mV |
| Current |
0.03% + |
6 mA |
3 mA |
2 mA |
1.2 mA |
0.6 mA |
0.4 mA |
| Readback accuracy (via GPIB or keyboard display at 25&186;C ±5ºC) |
| Voltage |
0.02%+ |
2 mV |
5 mV |
8 mV |
16 mV |
32 mV |
54 mV |
| Current |
0.02%+ |
6 mA |
3 mA |
2 mA |
1 mA |
0.6 mA |
0.3 mA |
| Ripple and noise (20 Hz to 20 MHz) |
| Constant Voltage rms |
2 mV |
3 mV |
5 mV |
9 mV |
18 mV |
30 mV |
| peak-peak |
5 mV |
7 mV |
10 mV |
15 mV |
25 mV |
50 mV |
| Constant Current rms |
8 mA |
4 mA |
2 mA |
1 mA |
1 mA |
1 mA |
| Line regulation |
| Voltage |
0.5 mV |
0.5 mV |
1 mV |
2 mV |
3 mV |
5 mV |
| Current |
0.75 mA |
0.5 mA |
0.3 mA |
0.1 mA |
50 μA |
30 μA |
| Load regulation |
| Voltage |
1 mV |
1 mV |
1 mV |
2 mV |
4 mV |
7 mV |
| Current |
0.5 mA |
0.2 mA |
0.2 mA |
0.1 mA |
50 μA |
30 μA |
| Transient response time |
Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of rated current |
|