| Input Voltage |
115 or 230VAC ± 20% auto-ranging 47Hz - 440Hz |
| Input Protection |
Thermal fuse Inrush current limiting |
| Input Isolation |
2250VDC input to chassis 2250 VDC input to output 8mm spacing 2250VDC output to chassis |
| Full compliance to IEC950, CSA C22.2 No. 950 and UL 1950 |
| Output Voltage |
0 … 250V range; max current 2A |
| Output frequency |
47 …424Hz in one band 50,100,200,400Hz ‘hot’ push buttons |
| Wave Form |
Sinusoidal |
| Total Harmonic Distortion |
Less than 5% at full load |
| Efficiency |
Min 78% at full load |
| Line Regulation |
Maximum 0.5% |
| Load Regulation |
Maximum ±6% from 10% load to full load |
| Output Protection |
Current limiting with short circuit protection. Thermal shutdown with automatic recovery in case of insufficient airflow |
| EMI |
Typically meets EN 55022 Class B |
| Load Crest Factor |
Maximum 3.0 at 90% load |
| Operating Temperature Range |
0°C to +50°C |
| Frequency Stability |
±0.1% |
| Temperature Drift (for output voltage level) |
0.05% per °C over operating temperature range |
| Dimensions |
8.5” x 5.1” x 14” enclosed case (WxHxL) |
| Connections |
Input: IEC inlet connector Output: banana sockets or standard AC receptacle |
| Weight |
9 pounds (4.1kg) |
| Warranty |
Twelve months subject to application within good engineering practice. |