AEMC 6250 Specifications |
Range |
5.000mΩ / 25.000mΩ / 250.00mΩ / 2500.0mΩ / 25.000Ω / 250.00Ω / 2500.0Ω |
Accuracy |
0.05% + 0.5μΩ / 0.05% + 3μΩ / 0.05% + 30μΩ / 0.05% + 0.3mΩ / 0.05% + 3mΩ / 0.05% + 30mΩ / 0.05% + 300mΩ |
Resolution |
0.1μΩ / 1μΩ / 10μΩ / 0.1mΩ / 1mΩ / 10mΩ / 100mΩ |
Test Current |
10A / 10A / 10A / 1A / 100mA / 10mA / 1mA |
Measurement Mode |
Selectable: Inductive (continuous test), Resistive (instantaneous test), Auto (multiple tests) |
Metal Type |
Selectable: Copper, Aluminum, or Other metal. Programmable from 000.00 to 99.99 |
Temperature Correction |
Manual or automatic with 0.1° resolution. Programmable from 32° to 130°F or -10° to 130°C |
Temperature Probe |
100Ω platinum RTD, 0.1°F Resolution, ±0.9°F Accuracy |
Alarms |
Two - programmable setpoints from 0.0 to 2500.0Ω |
Buzzer |
Programmable on/off and volume level |
Power Source |
Rechargeable 6V, 8.5 Ah NiMH batteries |
Battery Life |
Approx. 5000 10A tests |
Battery Charging |
120/240Vac ± 20% line voltage |
Power Management |
Display powers down after 1, 5, or 10 minutes of inactivity |
Memory |
Stores up to 1500 test results |
Mechanical Specifications |
Dimensions |
10.63" x 9.84" x 7.09" |
Weight |
8.1 lbs (3.69kg) |
Display Specification |
Display Type |
Large 50,000-count digital |
Size |
4 x 2.25" (102 x 57mm) |
Backlight |
Blue electroluminescent |
Color |
Safety yellow case; grey faceplate |
Communications Specifications |
Interface Port |
PC, remote terminal, printer, or trigger test from remote contact closure |
Environmental Specifications |
Operating Temperature |
14° to 132°F(-10° to 55°C) 80% RH (non-condensing) |
Storage Temperature |
-40° to 140°F(-40° to 60°C) |
Safety Specifications |
Safety Rating |
EN 61010-1, 60V Cat. II |
Double Insulation |
Yes |
CE Mark |
Yes |